BXNPY - 19071 PTH ACCELERATOR 9071
- MSDS: BXNPY
- Manufacturer: MACDERMID INC
- Product Name: 19071 PTH ACCELERATOR 9071
- National Stock Number: 6850-00F041371
Product Identification
Product ID:19071 PTH ACCELERATOR 9071
MSDS Date:09/15/1987
FSC:6850
NIIN:00F041371
MSDS Number: BXNPY
Responsible Party
WATERBURY, CT 06720-5000
US
Emergency Phone: 203-575-5700/313-644-5626
Info Phone: 203-575-5700/313-644-5626
Cage: 1FK56
Contractor
Telephone: 203-575-5700
Cage: 1FK56
Ingredients
HYDROGEN TETRAFLUOROBORATE (HYDROFLUOBORIC ACID)
CAS: 16872-11-0
RTECS: ED2685000
Fraction By Weight: 45%
OSHA PEL 2.5 MG/CUM (F)
Hazards
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IRRITATION & BURNS TO EYES, SKIN &
MUCOUS MEMBRANES.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, SCLEROSIS OF BONES & CALCIFICATION
OF LIGAMENTS.
Medical Cond Aggravated by Exposure:ASTHMA
First Aid
First Aid:EYES: FLUSH W/WATER FOR 15 MINS. SKIN: WASH W/SOAP & WATER.
INGESTION: GIVE WATER. DON'T INDUCE VOMITING. INHALATION: REMOVE TO
FRESH AIR. OBTAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Flash Point:NON-FLAMMABLE
Extinguishing Media:USE MEDIA APPROPRIATE FOR SURROUNDING AREAS.
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS & FULL
PROTECTIVE CLOTHING.
Accidental Release
Spill Release Procedures:NEUTRALIZE & FLUSH W/COLD WATER TO CHEMICAL
DRAIN.
Handling
Handling and Storage Precautions:STORE IN A COOL, VENTILATED AREA IN
TIGHTLY CLOSED CONTAINERS.
Other Precautions:AVOID EYE & SKIN CONTACT.
Exposure Controls
Respiratory Protection:NOT NORMALLY REQUIRED.
Ventilation:LOCAL EXHAUST
Protective Gloves:RUBBER
Eye Protection:SPLASH PROOF GOGGLES/FACE SHIELD
Other Protective Equipment:RUBBER APRON, RUBBER BOOTS.
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:266F
Vapor Pres:AQUEOUS
Spec Gravity:1.37
pH:<1
Evaporation Rate & Reference:(WATER =1): <1
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS TO VERY PALE YELLOW LIQUID W/SLIGHT ACRID
ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
CYANIDES, CORROSIVE TO FERROUS & COPPER ALLOYS, STRONG BASES.
Hazardous Decomposition Products:FLUORIDE VAPORS & BORON OXIDES.
Disposal
Waste Disposal Methods:FLUORIDES CAN BE PRECIPITATED W/LIME. DISCHARGE
NEUTRALIZED SOLUTION TO DRAIN W/LARGE AMOUNTS OF COLD WATER.
DISPOSE OF IAW/FEDERAL, STATE & LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.